Analisis Efektivitas dan Efisiensi Kinerja IPAL Domestik di MGS Menggung PT. Pertamina EP Cepu

Bahasa Indonesia

Authors

  • syintia Vatma Kusuma harum Universitas Islam Negeri Sunan Ampel Surabaya
  • Nadinda Aisyah Kamila Universitas Islam Negeri Sunan Ampel Surabaya
  • Rifat Adine Pratama Universitas Islam Negeri Sunan Ampel Surabaya

DOI:

https://doi.org/10.33506/ceej.v3i1.4954

Keywords:

Air Limbah domestik, Efisiensi Pengolahan, Total Suspended Solid (TSS), Total Coliform

Abstract

Domestic wastewater produced by industrial areas, although not directly derived from the production process, still has the potential to cause environmental pollution if not properly treated. This waste generally contains organic pollutants, nutrients, oil and fat, and pathogenic microorganisms. If not properly treated, waste discharge into water bodies can increase BOD, COD, TSS, Oil and Greaset, Ammonia, and Total Coliform levels, which have an impact on water quality degradation. This study aims to evaluate the effectiveness of the performance of the Wastewater Treatment Plant (WWTP) at PT MGS Menggung PT Pertamina EP Cepu by utilizing primary data through field observations and interviews, as well as secondary data in the form of laboratory test results for the period July–December 2024. The evaluation was carried out on six wastewater quality parameters, namely Biochemical Oxygen Demand (BOD), Chemical Oxygen Demand (COD), Total Suspended Solids (TSS), Oil and Grease, Ammonia, and Total Coliform. The analysis results show that the average BOD reduction efficiency is 42.8% and COD is 52.31%, which is considered quite effective. Conversely, the reduction efficiency of TSS (38.80%) and Total coliform (39.32%) was still less than optimal. This low efficiency indicates the need for improvements in the sedimentation and disinfection units. Therefore, it is recommended to add a coagulation-flocculation process and optimize the chlorination system to improve WWTP performance so that the treated product meets domestic wastewater quality standards as stipulated in applicable regulations

References

1. United Nations Environment Programme (UNEP). Wastewater Management A UN-Water Analytical Brief. In 2021. p. 1–52.

2. Yusof, N., Lau, W. J., & Ismail AF. Recent trends of heavy metal removal from water/wastewater by membrane technologies. Journal of Industrial and Engineering Chemistry. 2019;76:17–28. 3. Syarif, F., & Yuningsih S. Evaluasi Kinerja IPAL Domestik pada Kawasan Industri di Indonesia. Jurnal Teknik Lingkungan. 2020;26:187–195.

4. Arifin, A., & Pratama YA. mampuan Hybrid Anaerobic Baffled Reactor (ABR) Biofilter dalam Menurunkan Total Nitrogen dan Fosfor pada Air Limbah Apartemen. Jurnal Ilmu Lingkungan. 2023;21:574–80.

5. Metcalf & Eddy Inc, Tchobanoglous G, Stensel H, Tsuchihashi R, Burton F. Wastewater Engineering: Treatment and Resource Recovery. 1994;

6. Abma WR, Driessen W, Haarhuis R, van Loosdrecht MCM. Upgrading of sewage treatment plant by sustainable and cost-effective separate treatment of industrial wastewater. Water Science and Technology. 2010 Apr 1;61(7):1715–22.

7. Kurniawan R, et al. Optimasi proses biofilter aerob dan sedimentasi. 2021

8. Putri A, Pratama D. Analisis kinerja IPAL dalam penurunan beban pencemar. 2020.

9. Rahman A, et al. Efektivitas biofilter dalam menurunkan TSS pada IPAL domestik. 2019

10. Rusten B, Eikebrokk B, Ulgenes Y, Lygren E. Design and operations of the Kaldnes moving bed biofilm reactors. Water Sci Technol. 1995;32(8):53–60. doi:10.2166/wst.1995.0312

11. Soeparman HM, Suparmin. Pembuangan tinja dan limbah cair: suatu pengantar. Jakarta: Penerbit

Buku Kedokteran EGC; 2001.

12. Trisyanti D, Soedjono ES, Purnama IL. Domestic wastewater management in Indonesia: a review. IOP Conf Ser Earth Environ Sci. 2017;70(1):012031. doi:10.1088/1755-1315/70/1/012031

Published

2025-10-30

How to Cite

harum, syintia V. K., Kamila, N. A., & Pratama, R. A. (2025). Analisis Efektivitas dan Efisiensi Kinerja IPAL Domestik di MGS Menggung PT. Pertamina EP Cepu: Bahasa Indonesia. Casuarina: Environmental Engineering Journal, 3(1), 128–135. https://doi.org/10.33506/ceej.v3i1.4954

Similar Articles

<< < 1 2 3 > >> 